Module nguồn AC-DC 5V HLK-PM01

Giá gốc: 60.000₫

Giá khuyến mại 55.000₫

1. Product features:

  • All voltage input (AC: 90 ~ 264V)
  • Output overload and short circuit protection
  • Meet UL, CE requirements,
  • Ultra-thin, ultra-small
  • The product is designed to meet the requirements of EMC and Safety Test
  • High efficiency, high power density
  • Low ripple and low noise
  • 100% load aging and testing
  • Low power consumption, environmental protection, no-load loss <0.1W

2. Environment Condition

Item Name Technical Criteria   Unit
Operation Temperature -20—+60
Store Temperature -40—+80
Relative humidity 5—95 %
Cooling way Cooling by radiation  
Atmospheric pressure 80—106 Kpa
Sea level elevation ≤2000 m
Vibration Vibration coefficient 10~500Hz,2G10min./1cycle, 60min.each along X,Y,Z axes  

3.Electrical Characteristic
Input characteristics (test at room temperature 20 ).

Item Name Technical Criteria Unit
Rated input voltage 100-240 VAc
Input voltage range 90-264 VAc
Maximum input current ≤0.2 A
Input current surge ;                  ≤10 A
maximum input voltage ≤270 VAc
Enter slow start ≤50 mS
Input Low Voltage Efficiency Vin=110VAc,Output full-load≥69 %
Input High Voltage Efficiency Vin=220VAc,output full-load≥70 %
Long-term reliability MTBF≥100,000 h
Load rated output voltage +5±0.1

VDc

Full rated output voltage +5±0.2

VDc

Short-term maximum output current ≥1000 mA
The maximum output current for a long time ≥600 mA
Voltage Regulation ±0.2   %
Load Regulation                       ±0.5 %
Output ripple and noise
(mVp-p)
≤50
Rated input voltage, full load. Using 20MHz of bandwidth,
The load side 10uF and 0.1uF capacitor to be tested.
mV
Switch overshoot amplitude (Rated input voltage and output load plus 10%)≤5 %VO
Output over-current protection 150-200% of the output maximum load A
Output short circuit protection Direct short circuit at the normal output, automatically resume normal operation after a short circuit removal  

Vật Tư Giá Sỉ - Tổng Kho Solar