AC Servo Drives with Built-in EtherCAT Communications [1S-series]
General Specifications
Item | Specifications | ||
---|---|---|---|
Operating ambient temperature and humidity | 0 to 55°C, 90% max. (with no condensation) | ||
Storage ambient temperature and humidity | -20 to 65°C, 90% max. (with no condensation) | ||
Operating and storage atmosphere | No corrosive gases | ||
Operating altitude | 1,000 m max. | ||
Vibration resistance | 10 to 60 Hz and at an acceleration of 5.88 m/s2 or less (Not to be run continuously at the resonance frequency) |
||
Insulation resistance | Between power supply terminals/power terminals and PE terminals: 0.5 MΩ min. (at 500 VDC) |
||
Dielectric strength | Between power supply terminals/power terminals and PE terminals: 1,500 VAC for 1 min (at 50/60 Hz) |
||
Protective structure | IP20 (Built into IP54 panel) | ||
International standard |
EU Directives |
EMC Directive | EN 61800-3 second environment, C3 category (EN61326-3-1 *1; Functional Safety) |
Low Voltage Directive |
EN 61800-5-1 | ||
Machinery Directive | EN ISO 13849-1 (Cat.3), EN 61508, EN 62061, EN 61800-5-2 | ||
UL standards | UL 61800-5-1 | ||
CSA standards | CSA C22.2 No. 274 | ||
Korean Radio Regulations (KC) | Compliant | ||
Australian EMC Labelling Requirements (RCM) |
Compliant | ||
EAC requirements | Compliant | ||
SEMI standards | Can conform to the standard for momentary power interruptions (for no-load operation). |
||
Ship standards (NK/LR) | Not compliant |
* The following product models are applicable to EN61000-6-7.
Applicable models: R88D-1SN55[]-ECT, R88D-1SN75[]-ECT, R88D-1SN150[]-ECT
Note: The above items reflect individual evaluation testing. The results may differ under compound conditions.
The detail of Machinery Directive is as follows:
The STO function via safety input signals: EN ISO 13849-1 (Cat3 PLe), EN 61508 (SIL3), EN 62061 (SIL3), EN 61800-5-2 (STO)
The STO function via EtherCAT communications: EN ISO 13849-1 (Cat.3 PLd), EN 61508 (SIL2), EN 62061 (SIL2), EN 61800-5-2 (STO)
Precautions for Correct Use
Disconnect all connections to the Servo Drive before attempting a megger test (insulation resistance measurement) on a Servo Drive. Not doing so may result in the Servo Drive failure.
Do not perform a dielectric strength test on the Servo Drive. Internal elements may be damaged.